Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38582974

RESUMO

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Assuntos
Cardiomiopatias , Ablação por Cateter , Criocirurgia , Taquicardia Ventricular , Idoso , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/complicações , Criocirurgia/efeitos adversos , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Temperatura , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Cateteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
CJC Open ; 5(8): 611-618, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37720184

RESUMO

Patients with new-onset left bundle branch block (LBBB) after transcatheter aortic valve implantation (TAVI) are at risk of developing delayed high-degree atrioventricular block. Management of new-onset LBBB post-TAVI remains controversial. In the Comparison of a Clinical Monitoring Strategy Versus Electrophysiology-Guided Algorithmic Approach in Patients With a New LBBB After TAVI (COME-TAVI) trial, consenting patients with new-onset LBBB that persists on day 2 after TAVI, meeting exclusion/inclusion criteria, are randomized to an electrophysiological study (EPS)-guided approach or 30-day electrocardiographic monitoring. In the EPS-guided approach, patients with a His to ventricle (HV) interval ≥ 65 ms undergo permanent pacemaker implantation. Patients randomized to noninvasive monitoring receive a wearable continuous electrocardiographic recording and transmitting device for 30 days. Follow-up will be performed at 3, 6, and 12 months. The primary endpoint is a composite outcome designed to capture net clinical benefit. The endpoint incorporates major consequences of both strategies in patients with new-onset LBBB after TAVI, as follows: (i) sudden cardiac death; (ii) syncope; (iii) atrioventricular conduction disorder requiring a pacemaker (for a class I or IIa indication); and (iv) complications related to the pacemaker or EPS. The trial incorporates a Bayesian design with a noninformative prior, outcome-adaptive randomization (initially 1:1), and 2 prespecified interim analyses once 25% and 50% of the anticipated number of primary endpoints are reached. The trial is event-driven, with an anticipated upper limit of 452 patients required to reach 77 primary outcome events over 12 months of follow-up. In summary, the aim of this Bayesian multicentre randomized trial is to compare 2 management strategies in patients with new-onset LBBB post-TAVI-an EPS-guided approach vs noninvasive 30-day monitoring. Trial registration number: NCT03303612.


Les patients chez qui un bloc de branche gauche (BBG) est récemment apparu à la suite de l'implantation valvulaire aortique par cathéter (IVAC) présentent un risque de bloc auriculoventriculaire de haut degré tardif. La prise en charge d'un BBG récemment apparu après une IVAC demeure controversée. Dans le cadre de l'essai COME-TAVI (Comparison of a ClinicalMonitoring Strategy VersusElectrophysiology-Guided Algorithmic Approach in Patients With a New LBBB AfterTAVI, ou comparaison d'une stratégie de surveillance clinique, par rapport à une approche guidée par étude électrophysiologique et fondée sur un algorithme, chez des patients présentant un BBG d'apparition récente à la suite d'une IVAC), des patients qui présentent un BBG d'apparition récente persistant le 2e jour après une IVAC, qui répondent aux critères d'admissibilité et qui ont donné leur consentement sont répartis aléatoirement pour être suivis à l'aide d'une approche guidée par une étude électrophysiologique (EEP) ou faire l'objet d'une surveillance électrocardiographique d'une durée de 30 jours. Un stimulateur cardiaque est implanté chez les patients du groupe de l'EEP dont l'intervalle HV (temps de conduction dans le tronc du faisceau de His jusqu'aux ventricules) est ≥ 65 ms. Les patients du groupe de surveillance non invasive reçoivent un dispositif portable d'enregistrement et de transmission continue de données électrocardiographiques pour une période de 30 jours. Le suivi sera réalisé aux 3e, 6e et 12e mois. Le critère d'évaluation principal est un paramètre composite conçu afin de saisir le bienfait clinique net. Il comprend les conséquences majeures des deux stratégies chez les patients présentant un BBG d'apparition récente après une IVAC, comme suit : (i) mort subite d'origine cardiaque; (ii) syncope; (iii) trouble de la conduction auriculoventriculaire nécessitant la pose d'un stimulateur cardiaque (pour une indication de classe I ou IIa); et (iv) complications relatives au stimulateur cardiaque ou à l'EEP. L'essai intègre une conception bayésienne avec une répartition aléatoire (dans un rapport initial de 1:1) antérieure non informative adaptée aux résultats et deux analyses intermédiaires définies au préalable lorsque 25 % et 50 % du nombre anticipé des critères d'évaluation principaux seront atteints. L'essai est axé sur les événements, et la limite supérieure anticipée pour atteindre 77 événements relatifs aux critères d'évaluation principaux sur 12 mois de suivi est de 452 patients. En résumé, l'objectif de cet essai bayésien multicentrique à répartition aléatoire est de comparer deux stratégies de prise en charge de patients présentant un BBG d'apparition récente après une IVAC, soit une approche guidée par une EEP, par rapport à une surveillance non invasive de 30 jours. Trial registration number: NCT03303612.

6.
Eur Heart J Acute Cardiovasc Care ; 12(9): 571-581, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37319361

RESUMO

AIMS: Heart transplantation (HT) can be proposed as a therapeutic strategy for patients with severe refractory electrical storm (ES). Data in the literature are scarce and based on case reports. We aimed at determining the characteristics and survival of patients transplanted for refractory ES. METHODS AND RESULTS: Patients registered on HT waiting list during the following days after ES and eventually transplanted, from 2010 to 2021, were retrospectively included in 11 French centres. The primary endpoint was in-hospital mortality. Forty-five patients were included [82% men; 55.0 (47.8-59.3) years old; 42.2% and 26.7% non-ischaemic dilated or ischaemic cardiomyopathies, respectively]. Among them, 42 (93.3%) received amiodarone, 29 received (64.4%) beta blockers, 19 (42.2%) required deep sedation, 22 had (48.9%) mechanical circulatory support, and 9 (20.0%) had radiofrequency catheter ablation. Twenty-two patients (62%) were in cardiogenic shock. Inscription on wait list and transplantation occurred 3.0 (1.0-5.0) days and 9.0 (4.0-14.0) days after ES onset, respectively. After transplantation, 20 patients (44.4%) needed immediate haemodynamic support by extracorporeal membrane oxygenation (ECMO). In-hospital mortality rate was 28.9%. Predictors of in-hospital mortality were serum creatinine/urea levels, need for immediate post-operative ECMO support, post-operative complications, and surgical re-interventions. One-year survival was 68.9%. CONCLUSION: Electrical storm is a rare indication of HT but may be lifesaving in those patients presenting intractable arrhythmias despite usual care. Most patients can be safely discharged from hospital, although post-operative mortality remains substantial in this context of emergency transplantation. Larger studies are warranted to precisely determine those patients at higher risk of in-hospital mortality.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/etiologia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodos
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37038759

RESUMO

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes
8.
Expert Rev Cardiovasc Ther ; 21(3): 227-236, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36852632

RESUMO

BACKGROUND: Robotic magnetic navigation (RMN) has emerged as a potential solution to overcome challenges associated with catheter ablation of arrhythmias in patients with congenital heart disease (CHD). OBJECTIVES: To assess safety and efficacy of RMNguided catheter ablation in patients with CHD. DESIGN AND METHODS: A systematic review and pooled analysis was conducted on patients with CHD who underwent RMNguided catheter ablation. Random effects models were used to generate pooled estimates with the inverse variance method used for weighting studies. RESULTS: Twentyfour nonoverlapping records included 167 patients with CHD, mean age 36.5 years, 44.6% female. Type of CHD was simple in 27 (16.2%), moderate in 32 (19.2%), and complex in 106 (63.5%). A total of 202 procedures targeted 260 arrhythmias, the most common being macroreentrant atrial circuits. The mean procedural duration was 207.5 minutes, with a mean fluoroscopy time of 12.1 minutes. The pooled acute success rate was 89.2% [95% CI (77.8%, 97.4%)]. Freedom from arrhythmia recurrence was 84.5% [95% CI (72.5%, 94.0%)] over a mean follow-up of 24.3 months. The procedural complication rate was 3.5% with no complication attributable to RMN technology. CONCLUSION: RMN-guided ablation appears to be safe and effective across a variety of arrhythmia substrates and types of CHD.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Adulto , Masculino , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Cardiopatias Congênitas/complicações , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos
9.
Heart Rhythm O2 ; 3(5): 560-567, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36340481

RESUMO

Background: The identification of low-voltage proarrhythmic areas for catheter ablation of scar-mediated ventricular tachycardia (VT) remains challenging. Integration of myocardial perfusion imaging (single-photon emission computed tomography/computed tomography; SPECT/CT) and electroanatomical mapping (EAM) may improve delineation of the arrhythmogenic substrate. Objective: To assess the feasibility of SPECT/CT image integration with voltage maps using the EnSite Precision system (Abbott) in patients undergoing scar-mediated VT ablation. Methods: Patients underwent SPECT/CT imaging prior to left ventricular (LV) EAM with the EnSite Precision mapping system. The SPECT/CT, EAM data, and ablation lesions were retrospectively co-registered in the EnSite Precision system and exported for analysis. Segmental tissue viability scores were calculated based on SPECT/CT perfusion and electrogram bipolar voltage amplitude. Concordance, specificity, and sensitivity between the 2 modalities as well as the impact of SPECT/CT spatial resolution were evaluated. Results: Twenty subjects (95% male, 67 ± 7 years old, left ventricular ejection fraction 36% ± 11%) underwent EAM and SPECT/CT integration. A concordance of 70% was found between EAM and SPECT/CT for identification of cardiac segments as scar vs viable, with EAM showing a 68.5% sensitivity and 76.4% specificity when using SPECT/CT as a gold standard. Projection on low-resolution 3D geometries led to an average decrease of 38% ± 22% of the voltage points used. Conclusion: The study demonstrated the feasibility of integrating SPECT/CT with EAM performed retrospectively for characterization of anatomical substrates during VT ablation procedures.

10.
Circ Arrhythm Electrophysiol ; 15(8): e010347, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35776711

RESUMO

BACKGROUND: Ablation of ventricular tachycardia (VT) is limited by the inability to create penetrating lesions to reach intramyocardial origins. Intramural needle ablation using in-catheter, heated saline-enhanced radio frequency (SERF) energy uses convective heating to increase heat transfer and produce deeper, controllable lesions at intramural targets. This first-in-human trial was designed to evaluate the safety and efficacy of SERF needle ablation in patients with refractory VT. METHODS: Thirty-two subjects from 6 centers underwent needle electrode ablation. Each had recurrent drug-refractory monomorphic VT after implantable cardioverter defibrillator implantation and prior standard ablation. During the SERF study procedure, one or more VTs were induced and mapped. The SERF needle catheter was used to create intramural lesions at targeted VT site(s). Acute procedural success was defined as noninducibility of the clinical VT after the procedure. Patients underwent follow-up at 30 days, and 3 and 6 months, with implantable cardioverter defibrillator interrogation at follow-up to determine VT recurrence. RESULTS: These refractory VT patients (91% male, 66±10 years, ejection fraction 35±11%; 56% ischemic, and 44% nonischemic) had a median of 45 device therapies (shock/antitachycardia pacing) for VT in the 3 to 6 months pre-SERF ablation. The study catheter was used to deliver an average of 10±5 lesions per case, with an average of 430±295 seconds of radiofrequency time, 122±65 minute of catheter use time, and a procedural duration of 4.3±1.3 hours. Acute procedural success was 97% for eliminating the clinical VT. At average follow-up of 5 months (n=32), device therapies were reduced by 89%. Complications included 2 periprocedural deaths: an embolic mesenteric infarct and cardiogenic shock, 2 mild strokes, and a pericardial effusion treated with pericardiocentesis (n=1). CONCLUSIONS: Intramural heated saline needle ablation showed complete acute and satisfactory mid-term control of difficult VTs failing 1 to 5 prior ablations and drug therapy. Further study is warranted to define safety and longer-term efficacy. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique Identifier: NCT03628534 and NCT02994446.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Ablação por Cateter/métodos , Estudos de Viabilidade , Feminino , Temperatura Alta , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
11.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33157186

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Assuntos
Fibrilação Atrial , Ablação por Cateter/efeitos adversos , Angiografia por Ressonância Magnética , Complicações Pós-Operatórias , Veias Pulmonares , Estenose de Veia Pulmonar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Humanos , Incidência , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/epidemiologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/fisiopatologia
12.
N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32374963

RESUMO

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Reutilização de Equipamento , Infecções/etiologia , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Estudos de Casos e Controles , Países em Desenvolvimento , Feminino , Seguimentos , Humanos , Incidência , Infecções/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mortalidade , Fatores de Risco , Esterilização
13.
Expert Opin Pharmacother ; 20(17): 2101-2114, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31566420

RESUMO

Introduction: Ventricular arrhythmias are often seen in association with structural heart disease. However, approximately a tenth of affected patients have apparently normal hearts, where such arrhythmias typically occur in young patients, are sometimes inherited and can occasionally lead to sudden cardiac death (SCD). Over the past two decades, increased understanding of the underlying pathophysiology resulted in improved targeted pharmacological therapy.Areas covered: This article reviews current knowledge regarding drug therapy for inherited arrhythmia syndromes (Brugada, early repolarization, long QT and short QT syndromes, and catecholaminergic polymorphic ventricular tachycardia), and acquired arrhythmias (idiopathic ventricular fibrillation, short-coupled torsade de pointes, outflow tract ventricular tachycardia, idiopathic left, papillary muscle and annular ventricular tachycardias).Expert opinion: In inherited arrhythmia syndromes, appropriate clinical and genetic diagnoses followed by proper selection and dosing of antiarrhythmic drugs are of utmost importance to prevent SCD, most often without the need of implantable cardioverter-defibrillators. In acquired arrhythmias, appropriate pharmacotherapy in selected patients can also provide symptomatic relief and avoid the need for invasive therapy. Further research is needed to develop novel antiarrhythmic drugs or targeted therapy to increase efficacy and limit side effects.


Assuntos
Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Antagonistas Adrenérgicos beta/uso terapêutico , Arritmias Cardíacas/genética , Arritmias Cardíacas/patologia , Síndrome de Brugada/tratamento farmacológico , Síndrome de Brugada/patologia , Estudos de Associação Genética , Humanos , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/patologia , Quinidina/uso terapêutico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/patologia
14.
Can J Cardiol ; 35(8): 1069-1077, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31376908

RESUMO

BACKGROUND: Compelling evidence showing a link between atrial fibrillation (AF) and cognitive decline and dementia is accumulating. METHODS: Blinded Randomized Trial of Anticoagulation to Prevent Ischemic Stroke and Neurocognitive Impairment in Atrial Fibrillation (BRAIN-AF) is a prospective, multicentric, double-blind, randomized-controlled trial, recruiting patients with nonvalvular AF and a low risk of stroke. Patients with a high risk of bleeding will be excluded from the study. Participants will be randomized to receive either rivaroxaban (15 mg daily) or standard of care (placebo in patients without vascular disease or acetylsalicylic acid 100 mg daily in patients with vascular disease). RESULTS: The primary outcome is the composite of stroke, transient ischemic attack, and cognitive decline (defined by a decrease in the Montreal Cognitive Assessment score ≥ 3 at any follow-up visit after baseline). Approximately 3250 patients will be enrolled in approximately 130 clinical sites until 609 adjudicated primary outcome events have occurred. CONCLUSIONS: BRAIN-AF determines whether oral anticoagulation therapy with rivaroxaban compared with standard of care reduces the risk of stroke, transient ischemic attack, or cognitive decline in patients with nonvalvular AF and a low risk of stroke.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Disfunção Cognitiva , Rivaroxabana , Acidente Vascular Cerebral , Administração Oral , Adulto , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Coagulação Sanguínea/efeitos dos fármacos , Isquemia Encefálica/etiologia , Isquemia Encefálica/prevenção & controle , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/prevenção & controle , Método Duplo-Cego , Monitoramento de Medicamentos/métodos , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/efeitos adversos , Feminino , Humanos , Masculino , Testes de Estado Mental e Demência , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Rivaroxabana/administração & dosagem , Rivaroxabana/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
15.
World J Cardiol ; 11(5): 149-158, 2019 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-31171960

RESUMO

BACKGROUND: The prevalence of atrial fibrillation (AF) is on the rise in the aging population with congenital heart disease (CHD). A few case series have described the feasibility and early outcomes associated with radiofrequency catheter ablation of AF centered on electrically isolating pulmonary veins (PV) in patients with CHD. In contrast, cryoballoon ablation has not previously been studied in this patient population despite its theoretical advantages, which include a favorable safety profile and shorter procedural time. AIM: To assess the safety and feasibility of cryoballoon ablation for AF in an initial cohort of patients with CHD. METHODS: The study population consisted of consecutive patients with CHD and cryoballoon ablation for AF at the Montreal Heart Institute between December 2012 and June 2017. Procedural complications, acute success, and 1-year freedom from recurrent AF after a single procedure with or without antiarrhythmic drugs were assessed. Procedures were performed under conscious sedation. Left atrial access was obtained via a single transseptal puncture or through an existing atrial septal defect (ASD). Cryoballoon occlusion was assessed by distal injection of 50% diluted contrast into the pulmonary vein. At least one 240-second cryothermal application was performed upon obtaining complete pulmonary vein occlusion. Following ablation, patients were routinely followed at outpatient visits at 1, 3, 6, and 12 mo, and then annually. RESULTS: Ten patients, median age 57.9 (interquartile range 48.2-61.7) years, 60% female, met inclusion criteria and were followed for 2.8 (interquartile range 1.4-4.5) years. Two had moderately complex CHD (sinus venosus ASD with partial anomalous pulmonary venous return; aortic coarctation with a persistent left superior vena cava), with the remainder having simple defects. AF was paroxysmal in 8 (80.0%) and persistent in 2 (20.0%) patients. The pulmonary vein anatomy was normal in 6 (60.0%) patients. Four had left common PV (n = 3) and/or 3 right PV (n = 2). Electrical pulmonary vein isolation (PVI) was acutely successful in all. One patient had transient phrenic nerve palsy that recovered during the intervention. No major complication occurred. One year after a single ablation procedure, 6 (60%) patients remained free from AF. One patient with recurrent AF had recovered pulmonary vein conduction and underwent a second PVI procedure. A second patient had ablation of an extra-pulmonary vein trigger for AF. CONCLUSION: Cryoballoon ablation for AF is feasible and safe in patients with simple and moderate forms of CHD, with an excellent acute success rate and modest 1-year freedom from recurrent AF.

16.
CJC Open ; 1(5): 238-244, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32159115

RESUMO

BACKGROUND: Targeted temperature management (TTM) has been associated with an improvement in neurological function and survival in patients with cardiac arrest (CA) and an initially shockable rhythm. We report the Montreal Heart Institute (MHI) experience using TTM to evaluate mortality and neurological outcome in patients remaining in coma after CA, regardless of the initial rhythm. METHODS: We performed a retrospective review of all patients receiving TTM at the MHI between 2008 and 2015. Primary outcome was a composite of mortality and poor neurological outcome at hospital discharge. We also evaluated the long-term outcomes of those who initially survived to hospital discharge. RESULTS: A total of 147 patients (120 men, mean age 59.5 ± 12.5 years) underwent TTM at the MHI during the study period. Overall survival to hospital discharge with good neurological outcome was 45.6%. Shockable rhythm was associated with a better outcome (mortality odds ratio, 0.212; 95% confidence interval, 0.068-0.664; P = 0.008). Of the 11 initial survivors with a poor neurological status (Cerebral Performance Category ≥ 3), 4 died rapidly (within 1 month of hospital discharge), but 6 (54.5%) markedly improved their neurological status to Cerebral Performance Category 1. Long-term survival (mean follow-up of 38 ± 26 months) for those alive at hospital discharge (n = 76 patients) was 81.9%. CONCLUSION: Our retrospective analysis of CA survivors treated with TTM at MHI showed good survival, similar to the published results from the landmark randomized controlled trials, despite enrolling patients with nonshockable rhythms. A significant proportion of survivors with poor neurological outcome at discharge improved at follow-up.


CONTEXTE: Le contrôle ciblé de la température (CCT) a été associé à une amélioration de la fonction neurologique et de la survie chez les patients en arrêt cardiaque ayant un rythme initialement choquable. Nous présentons l'expérience d'utilisation du CCT à l'Institut de Cardiologie de Montréal (ICM) pour évaluer la mortalité et l'issue neurologique chez les patients qui demeurent comateux après un arrêt cardiaque, indépendamment du rythme initial. MÉTHODOLOGIE: Nous avons effectué une analyse rétrospective de tous les patients ayant fait l'objet d'un CCT à l'ICM entre 2008 et 2015. Le paramètre d'évaluation principal se composait de la mortalité et d'une évolution neurologique défavorable à la sortie de l'hôpital. Nous avons aussi évalué le devenir à long terme des patients ayant initialement survécu après leur congé. RÉSULTATS: Au total, 147 patients (120 hommes, âge moyen de 59,5 ± 12,5 ans) ont fait l'objet d'un CCT à l'ICM pendant la période d'étude. Le taux de survie globale jusqu'à la sortie de l'hôpital avec évolution neurologique favorable a été de 45,6 %. Un rythme choquable a été associé à une meilleure issue (rapport de cotes pour la mortalité = 0,212; intervalle de confiance à 95 % : de 0,068 à 0,664; p = 0,008). Chez les 11 survivants initiaux dont l'état neurologique était altéré (score CPC [Cerebral Performance Category] ≥ 3), 4 sont décédés peu après (dans le mois suivant leur congé), mais 6 (54,5 %) ont vu leur état neurologique s'améliorer considérablement jusqu'à un score CPC de 1. La survie à long terme (durée moyenne du suivi de 38 ± 26 mois) pour les patients vivants à leur sortie de l'hôpital (n = 76 patients) a été de 81,9 %. CONCLUSIONS: Notre analyse rétrospective des survivants d'un arrêt cardiaque traités par CCT à l'ICM a montré une bonne survie, comparable aux résultats publiés d'essais contrôlés phares à répartition aléatoire, malgré l'inscription de patients ayant des rythmes non choquables. Au moment du suivi, une amélioration a été observée chez une forte proportion des survivants dont l'état neurologique était altéré à leur sortie de l'hôpital.

18.
Expert Rev Cardiovasc Ther ; 16(7): 489-500, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29912584

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most frequent arrhythmia worldwide. While mostly seen in elderly, it can also affect young adults (≤ 45 years of age), older adolescent, and children. Areas covered: The aim of this review is to provide an overview of the current management of AF in young patients. Specific issues arise over diagnostic workup as well as antiarrhythmic and anticoagulation therapies. The future management and diagnostic strategies are also discussed. Expert commentary: Management of AF in the young adult is largely extrapolated from adult studies and guidelines. In this population, AF could reveal a genetic pathology (e.g. Brugada, Long QT or Short QT syndromes) or be the initial presentation of a cardiomyopathy. Therefore, thorough workup in the young population to eliminate potential malignant pathology.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Terapia Trombolítica/métodos , Adolescente , Adulto , Criança , Humanos , Adulto Jovem
19.
Europace ; 20(suppl_2): ii1-ii4, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29722859

RESUMO

Aims: Achieving adequate catheter tip-tissue contact is essential for delivering robust radiofrequency (RF) ablation lesions. We measured the contact force generated by a remote magnetic-guided catheter navigation system. Methods and results: A plexiglass model with an integrated scale was fashioned to mimic transvenous and retrograde access to sites in the right atrium and right and left ventricles. An 8 Fr RF ablation catheter was steered by remote magnetic guidance at fields of 0.08 and 0.10 T, with and without a long sheath positioned at the entrance of the chamber. Ten contact force readings were taken at each setting, with the scale recalibrated prior to each measurement. Generalized estimating equations were used to compare contact force measurements while adjusting for the non-independent data structure. A total of 240 contact force measurements were taken. Without a long sheath, contact forces with magnetic fields of 0.10 T (n = 60) and 0.08 T (n = 60) were similar (6.1 ± 1.4 g vs. 6.0 ± 1.3 g, P = 0.089). Contact forces were not significantly different with simulated transvenous (n = 80) and retrograde aortic (n = 40) approaches (6.2 ± 1.4 g vs. 5.7 ± 1.2 g, P = 0.132). The contact force increased substantially with a long sheath (P < 0.001) and was significantly higher with 0.10 T (n = 60) vs. 0.08 T (n = 60) fields (20.4 ± 0.6 g vs. 18.0 ± 0.5 g, P < 0.001). Conclusion: Magnetic fields of 0.08 and 0.10 T provide stable catheter contact forces, as reflected by the small variability between measurements. The average contact force is approximately 6 g without a sheath and increases to 20 g with a long sheath positioned at the entrance of the chamber of interest.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Magnetismo/métodos , Cirurgia Assistida por Computador/métodos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/anatomia & histologia , Ventrículos do Coração/anatomia & histologia , Humanos , Magnetismo/instrumentação , Imãs , Modelos Anatômicos , Modelos Cardiovasculares , Pressão , Cirurgia Assistida por Computador/instrumentação , Transdutores de Pressão
20.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29064134

RESUMO

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Assuntos
Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional/prevenção & controle , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Proteção , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...